Technical specifications
Mains voltage:230VAC
Power Factor:>0.98
Efficiency:>94%
Operating Frequency:28-80kHz
Starting:Preheat
Dimensions:250*141*50mm
Lamp status indication via LED indication
Green LED:Lamp on
Red LED:Lamp fault
Lamp status forwarding
Potential free relay contacts for lamp on/lamp fault..
Installation requirement
Wire Gauge:0.5-1.5mm2
Max.cable length between ballasts and lamp:5m
Relay contacts:potential free,
Load:50…500mA at 24…230V AC;
50…500mA at 5…60V DC
Mounting restrictions
Disconnect Input Power Before Installing or Servicing.
Ballast Case must Be Grounded.
Don’t short any two wires of the four outputs.
Features
RS485 dimmable function:
The lamp power can be adjusted from 60% to 100%.
Type
|
Input Voltage(V)
|
Input Power(W)
|
Input Current(A)
|
Power Per Lamp(W)
|
Lamp Current(A)
|
Weight(kg)
|
EVG2*300W/2.1A-PHplus B1
|
198-305
|
692
|
3.07
|
2*240-325
|
1.8-2.2
|
1.16
|